Komatsu — REMOVAL AND INSTALLATION

DISASSEMBLY AND ASSEMBLY PIVOT SHAFT REMOVAL AND INSTALLATION OF PIVOT SHAFT ASSEMBLY REMOVAL INSTALLATION 1. Remove the track frame assembly. For details, see Removal, installation of track frame assem- bly. Carry out installation in the reverse order to removal. [*1] 2 Mounting bolt: Adhesive (LT-2) 2. Remove the mounting bolts of pivot shaft assem- bly (1) (Leave 2 – 3 of them, however). [*1] 3 Mounting bolt: 823 – 1,029 Nm {84 – 105 kgm} 3. Sling pivot shaft assembly (1) temporarily and pull it out, using forcing screw [1]. 4 Pivot shaft assembly: 100 kg [*2] a Install the seal according to the following pro- cedure.

1) Reverse the seal (2) so that the relief let- ters a will be on the inside. 2) Install the reversed seal (2) to the shaft (1). 2 Seal: Oil (EO-30) 4. Remove seal (2) from pivot shaft assembly (1). [*2] a Use tool [2] to press fit ring (4). Press fitting of force: 23.2 – 42.7 kN {2.37 – 4.35 tons} a Check that press fitting dimension a of the seal from the shaft end is proper. Press fitting dimension a : 412 ± 1mm D85EX-15 30-169 (2)