Komatsu D155AX-6 — MEASURING COMPRESSION PRESSURE

30 Testing and adjusting SEN00679-01 7. Disconnect power supply connector EGC3 (6) of the engine controller. a Install the injector and fuel high-pressure tube according to the following procedure. a Before installing the injector, replace the copper gasket and O-ring with new ones. 1) Push in injector (11) with the hand to assemble holder (12) temporarily. 2) Tighten bolt (13) and washer (14) tempo- rarily. k If this connector is not disconnected, the engine will start during measure- ment and will be dangerous. Accord- ingly, be sure to disconnect this connector. k Cover the controller side and wiring harness side with vinyl sheets, etc. to prevent electric leakage and ground fault.

2 Spherical part of washer: Engine oil 3) Tighten sleeve nut (15) of the fuel high- pressure tube temporarily. 4) Tighten bolt (13) permanently. 3 Bolt: 58.8 – 73.5 Nm {6 – 7.5 kgm} 5) Tighten sleeve nut (15) permanently. 3 Sleeve nut: 39.2 – 49.0 Nm {4 – 5 kgm} 8. Turn the starting switch ON and set the machine monitor to Monitoring function of the service mode. q Monitoring code: 01002 Engine Speed a For the operating method, see Special functions of machine monitor (EMMS). a Install the injector wiring harness accord- ing to the following procedure. 1) Install the injector wiring harness to the rocker arm housing and fix the connector side with the plate.

2) Fix the intermediate clamp with the clip. 3) Tighten the nut on the injector side. 3 Nut: 2 ± 0.2 Nm {0.2 ± 0.02 kgm} 4) Secure the clamp and spacer with the bolt. 3 Rocker arm assembly mounting bolt: 93 – 103 Nm {9.5 – 10.5 kgm} a Adjust the valve clearance. For details, see Adjusting valve clearance. 3 Cylinder head cover mounting bolt: 29.4 – 34.3 kgm {3.0 – 3.5 kgm} 9. Rotate the engine with the starting motor and measure the compression pressure. a Read the pressure gauge pointer when it is stabilized. a When measuring the compression pres- sure, check that the engine speed is in the range of the measurement condition. 10.

After finishing measurement, remove the mea- suring instruments and return the removed parts. D155AX-6 13