Komatsu D155AX-6 — MEASURING BLOW-BY PRESSURE

SEN00679-01 30 Testing and adjusting Measuring blow-by pressure 1 value is judged abnormal, check for increase of oil consumption, bad exhaust gas color, deterioration of oil, high deterio- ration speed of oil, etc. which are related to the abnormal blow-by pressure. a Measuring instrument for blow-by pressure k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the lock posi- tion. a Measure the blow-by pressure under the fol- lowing conditions. q Engine coolant temperature: Within oper- ating range q Power train oil temperature: Within operat- ing range q Hydraulic oil temperature:

Within operat- ing range 1. Open the engine left side cover and left mud- guard. 4. After finishing measurement, remove the mea- suring instruments and return the removed parts. 2. Install nozzle [1] and hose [2] of blow-by checker F to the end of breather hose (1) and connect them to gauge [3]. 3. While running the engine at high idle, stall the torque converter and measure the blow-by pressure. a For the procedure for stalling the torque converter, see Measuring engine speed. a Normally, the blow-by pressure should be measured while the engine is operated at the rated output. In the field, however, an approximate value can be obtained by stalling the torque converter.

a If it is impossible to run the engine at the rated output or stall the torque converter, measure while the engine is running at high idle. The value obtained in this case is about 80% of the blow-by pressure at the rated output. a The blow-by pressure may vary largely with the engine condition. If the measured 14 D155AX-6 Symbol Part No. Part name F 799-201-1504 Blow-by checker