Komatsu D155AX-6 — BLEEDING AIR FROM FAN PUMP

30 Testing and adjusting SEN00679-01 7. While running the engine at high idle, measure the fan circuit oil pressure. Bleeding air from fan pump 1 a If the fan pump is removed and installed or its piping is disconnected and connected, bleed air from the fan pump case according to the following procedure. a Before starting the following work, check that the hydraulic oil level is normal. 1. Remove the left step cover. 2. Loosen air bleeder (1) and leave it for 15 min- utes. 8. After finishing measurement, remove the mea- suring instruments and return the removed parts. 3. After 15 minutes, start the engine and run it at low idle. 4.

After oil flows out of air bleeder (1), tighten air bleeder (1) and stop the engine. 3 Air bleeder: 7.8 – 9.8 Nm {0.8 – 1.0 kgm} D155AX-6 29