Komatsu D155AX-6 — ADJUSTING PARKING BRAKE LEVER

SEN00680-01 30 Testing and adjusting 3. Checking limit switch 1) Turn the starting switch ON and set the machine monitor to Monitoring function of the service mode. a Monitoring code: 40905 T/M Sw Input 1 a For the operating method, see "Spe- cial functions of machine monitor (EMMS)". 2) Check that the limit switch signal is input normally when parking brake lever (3) is set in the FREE position and LOCK posi- tion. q FREE position: Travel lock NC OFF, Travel lock NO ON q LOCK position: Travel lock NC ON, Travel lock NO OFF 16 D155AX-6