30 Testing and adjusting SEN00680-01 Emergency escape method when power train has trouble 1 a Tools for emergency escape 1. Emergency escape method with switch box (Using P1) a If the machine cannot be moved because of a trouble in the electric system of the power train control unit (travel direction, gear speed, steering), escape according to the following procedure. a The engine must be startable for the fol- lowing procedure. a If the engine cannot be started, see Emer- gency escape method with brake releas- ing device (Using P2). 3) Disconnect neutral safety relay NSF (2) and connect pins No. 3 and No. 5 of the connector on the wiring harness side. a Direct coupling circuit:
NSF (female) No. 3 io No. 5 a If connector PL1 is disconnected, a model selection error is made and neutral safety relay NSF is not driven. The above operation is performed to prevent this. k Do not turn the starting switch ON or start the engine before preparing the switch assembly and wiring harness P1 completely. 1) Connect wiring harness [2] to switch assembly [1] of emergency escape device P1 . k If the engine is started by this method, the neutral safety function does not work. Accordingly, before starting the engine, set the parking brake lever in the LOCK position and set the PCCS lever in the fully neutral position.
k Set the all gear speed switches of switch assembly [1] in the OFF position and set the directional switch in the P position to prevent the machine from starting sud- denly. k Start the engine by this method only in an emergency. If the engine does not start in another case, be sure to carry out troubleshooting and repair the trouble. 2) Open the left fender inspection cover and connect wiring harness [2] to connector PL1 (1). a The male housing and female hous- ing of connector PL1 are fixed with screws. a Connect the wiring harness to both male side and female side of connec- tor PL1 . D155AX-6 17 Symbol Part No.
Part name P 1 19M-06-32820 Switch assembly 17A-06-41410 Wiring harness 2 790-190-1601 Pump assembly