30 Testing and adjusting SEN00680-01 6) Operate the volume pump to raise the brake releasing oil pressure to the initial pressure. q Initial pressure: Approx. 2.74 MPa {Approx. 28 kg/cmІ} a Since the accumulator is installed in the circuit, the handle must be oper- ated 30 – 50 times to raise the oil pressure. a If the oil pressure does not rise above a certain level, the relief valve may be set to low pressure. In this case, adjust the set pressure of the relief valve. 7) Tow the machine to a safe place. a The brake releasing oil pressure low- ers gradually because of internal leakage and the brake is applied again in about 1 minute. Accordingly, work quickly.
a If the brake releasing pressure lowers to about 1.57 MPa {about 16 kg/cmІ}, the brake is applied. In this case, operate the volume pump again to raise the brake releasing pressure to the initial pressure. D155AX-6 19