Komatsu D155AX-6 — MEASURING AND ADJUSTING WORK EQUIPMENT AND HSS OIL PRESSURE

30 Testing and adjusting SEN00680-01 3. Adjusting HSS oil pressure a If the HSS oil pressure is abnormal, adjust it with HSS LS relief valve (6) according to the following procedure. a The 5-spool valve of the single tilt specifi- cation is shown in the figure (The dual tilt machine has the 6-spool valve). 1) While fixing adjustment screw (7), loosen locknut (8). 2) Adjust the pressure by rotating adjustment screw (7). a If the adjustment screw is q rotated to the right, the pressure is heightened. q rotated to the left, the pressure is lowered. a Quantity of adjustment per turn of ad- justment screw: Approx. 15.1 MPa {Approx.

154 kg/cmІ} 3) While fixing adjustment screw (7), tighten locknut (8). 3 Locknut: 68.6 – 78.5 Nm {7 – 8 kgm} 4) After finishing measurement, check the HSS oil pressure according to the above measuring method. D155AX-6 25