30 Testing and adjusting SEN00680-01 Measuring work equipment lock solenoid valve output pressure 1 a Measuring instruments for work equipment lock solenoid valve output pressure Symbol Part No. Part name S 1 799-101-5002 Hydraulic tester 790-261-1204 Digital hydraulic tester 2 799-401-3200 Adapter (03) k Stop the machine on level ground, lower the work equipment to the ground, stop the engine, and set the parking brake lever and work equipment lock lever in the LOCK position. a Measure the work equipment lock solenoid valve output pressure under the following con- dition. 4.
Run the engine at high idle, set the work equip- ment lock lever in the LOCK position and FREE position, and measure the solenoid valve output. a If the output pressure is as follows, the operation of the work equipment lock sole- noid valve is normal. q Hydraulic oil temperature: Within operat- ing range Work equipment lock lever Output pressure 1. Remove the control valve cover and discon- nect control valve inlet hose (1). LOCK position 0 MPa {0 kg/cmІ} 4 Control valve cover: 25 kg FREE position Same as control circuit basic pressure (See stan- dard value table) 2. Install adapter S2 and connect the discon- nected hose again. 5.
After finishing measurement, remove the mea- suring instrument and return the removed parts. 3. Install nipple [1] of hydraulic tester S1 and con- nect it oil pressure gauge [2]. a When using an analog oil pressure gauge, use one of 5.9 MPa {60 kg/cmІ}. D155AX-6 27