Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 Adjustment ID: 0009 (Pitch angle sensor initial cor- rection) Adjustment ID: 0010 (Fan 70% mode) q This adjustment code is used to make the power train controller recognize the zero point of the pitch angle sensor and to correct the installation error. a After the power train controller is replaced or the pitch angle sensor is removed and installed or replaced, be sure to carry out this adjust- ment once. q This adjustment code is used to set the cooling fan speed to about 70% forcibly. a Use this adjustment code for testing, adjusting, or troubleshooting when necessary. q Functions of function switches [F3]:

Increase adjustment value [FAN 70% SPEED MODE] [F4]: Decrease adjustment value [FAN 70% SPEED MODE] [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Unused q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save corrected value q Operating method: When this adjustment code is displayed, its function is effective and the cooling fan speed is controlled to about 70% of the maximum speed. a After this adjustment code is turned OFF, its function is ineffective. q Operating method: 1) Check that the machine is level. 2) Press [F6] and check that the alarm buzz- er sounds.

a If adjustment is carried out, displayed item [BODY PITCH ANGLE] changes to [0.0 °] (The other displayed items do not change). a Even if this adjustment code is turned off, the correction is effective. D155AX-6 49