Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

SEN00681-01 30 Testing and adjusting Adjustment ID: 0031 (Work equipment controller initialization) Adjustment ID: 0530 (Stall mode) q This adjustment code is used to initialize the specification code recognized by the work equipment controller and the set values of the memory in the controller. a After the work equipment controller is re- placed, be sure to carry out this adjustment once. q This adjustment code is used to set the fan speed in the 100% mode automatically and make it possible to set the preset (gear speed at start) to [F3-R3] to stall the torque converter. a The preset (gear speed at start) can be set to [F3-R3] only while this adjustment code is selected.

a Use this adjustment code for testing, adjusting, or troubleshooting when neces- sary. q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save setting q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Unused q Operating method: 1) Press [F6] and check that the alarm buzz- er sounds. 2) Check that the displayed specification code [CODE] has changed from [6x6] to [666]. a If specification code [666] is not displayed, the controller wiring harness or the con- troller unit may be defective.

a Even if this adjustment code is turned off, the setting is effective. q Mode setting information within screen [P-AUTO SFT MODE]: Automatic gearshift in P mode [E-AUTO SFT MODE]: Automatic gearshift in E mode [P-MANUAL SFT MODE]: Manual gearshift in P mode [E-MANUAL SFT MODE]: Manual gearshift in E mode q Operating method: When this adjustment code is displayed, its function is effective and the preset (gear speed at start) is set to [F3-R3]. k This adjustment code does not stall the torque converter automatically. Accordingly, operate the levers and pedals securely when stalling the torque converter (For the procedure for stalling the torque converter, see Mea- suring engine speed).

a After this adjustment code is turned OFF, its function is ineffective. 50 D155AX-6