Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 Adjustment ID: 0910 (Load record check mode) Adjustment ID: 1005 (Fan 100% mode) q This adjustment code is used to check the load on the machine, odometer, and reverse odom- eter. a Use this adjustment code for testing, adjusting, or troubleshooting when necessary. q This adjustment code is used to set the cooling fan speed to about 100% forcibly. It is also used to set the adjustment value of the maxi- mum speed. a Use this adjustment code for testing, adjusting, or troubleshooting when necessary. q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]:

Unused q Functions of function switches [F3]: Increase adjustment value [FAN 100% SPEED MODE] [F4]: Decrease adjustment value [FAN 100% SPEED MODE] [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Mode setting information within screen [1000 rpm SMR]: Time displayed by service meter in which engine speed was above 1,000 rpm [ODO METER FORWARD]: Total forward travel distance [ODO METER REVERSE]: Total reverse travel distance q Operating method: a When this adjustment code is displayed, its function is effective and the cooling fan speed is controlled to about 100% of the maximum speed.

1) Increase or decrease the adjustment value by pressing [F3] or [F4]. 2) When confirming the adjustment value, press [F6] and check that the alarm buzzer sounds. a After this adjustment code is turned OFF, its function is ineffective but the set adjust- ment value is effective. q Operating method: When this adjustment code is displayed, its function is effective and the load on the machine, odometer, and reverse odometer are displayed simultaneously. a The data cannot be reset. a After this adjustment code is turned OFF, its function is ineffective. D155AX-6 51