Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 Adjustment ID: 8011 (Ripper tilt lever max. BACK position adjustment) Adjustment ID: 8020 (Blade raising current correc- tion) q This adjustment code is used to make the work equipment controller recognize the maximum BACK position of the tilt potentiometer of the ripper control lever. a After the work equipment controller or ripper control lever is replaced, be sure to carry out this adjustment once. q This adjustment code is used to adjust the sen- sitivity of start of blade when the blade control lever is moved in the raising position with the blade fine mode OFF. a Use this adjustment code for work when nec- essary.

q Functions of function switches [F3]: Unused [F4]: Unused [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Functions of function switches [F3]: Increase adjustment value [Current offset] [F4]: Decrease adjustment value [Current offset] [F5]: Return to adjustment item selecting screen (ID inputting screen) [F6]: Save adjustment value q Operating method 1) Increase or decrease the adjustment val- ue by pressing [F3] or [F4]. 2) Press [F6] and check that the alarm buzz- er sounds. a If the engine speed has been adjusted, it is displayed. It can be adjusted repeat- edly, however. a It is not necessary to move the blade dur- ing adjustment.

After finishing adjust- ment, however, raise the blade and check that there is not a problem in the actual operation feel (Check with the blade fine control mode OFF). a Even if this adjustment code is turned off, the adjustment is effective. q Operating method 1) Operate the ripper control lever to the BACK stroke end of the tilting direction and keep it in that position. 2) Press [F6] and check that the alarm buzzer sounds. a Even if the adjustment is carried out, the displayed value does not change. a Even if this adjustment code is turned off, the adjustment is effective. a This adjustment code is used to make the controller recognize the maximum BACK position of the potentiometer.

It is not used to adjust the sensitivity of the ripper control lever. D155AX-6 65