OPERATION 6. Even after the engine is started, do not touch the work equipment control levers and the travel pedals, while the engine hydraulic pressure monitor lamp is still lighted. Remark If the engine oil pressure monitor does not go out even after 4 to 5 seconds have passed, stop the engine immediately. Check the oil level, check for leakage of oil, and take the necessary action. Remark Regardless of the ambient temperature, it is possible to start the engine preheating manually. 7. Turn the key in ignition switch (3) to the left from OFF position (A). The preheating monitor lights up and engine preheating starts.
(Preheating continues while the key in ignition switch (3) is held at the left position.) Remark During the preheating operation, the preheating monitor lights up to show that preheating is taking place. 8. After approximately 18 seconds, the preheating monitor will go out to inform that the preheating has been completed. 9. Turn the key in ignition switch (3) to START position (C). The engine will start. 2-88 PC300LC/HD-7E0