OPERATION 2. Check to be sure engine water temperature monitor (1) displays green. If it displays white, use the procedure in Step 3 to carry out additional warming up of the engine until the monitor displays green. 3. Turn fuel control dial (2) to a point midway between low idling (MIN) and full speed (MAX), run the engine at a mid-range speed, and run under no load until engine water temperature monitor (1) displays green. If the engine water temperature monitor displays green, the engine warming-up operation is completed. After checking that the engine water temperature monitor displays green, carry out the warming-up operation for the hydraulic equipment.
CANCELING AUTOMATIC WARMING-UP OPERATION If it becomes necessary in an emergency to cancel the automatic warming-up operation or to lower the engine speed to low idle, do as follows. 1. Turn fuel control dial (2) to the full speed (MAX) position and hold it for 3 seconds. 2. When fuel control dial (2) is returned to the low idle (MIN) posi- tion, the engine speed will drop. 2-90 PC300LC/HD-7E0