Komatsu — BUCKET REPLACEMENT

OPERATION REPLACING WORK IMPLEMENTS When the pin is knocked in with a hammer, pieces of metal may fly into your eyes and cause serious injury. When carrying out this operation, always wear goggles, hard hat, gloves, and other protective equipment. When the bucket is removed, place it in a stable condition. If the pins are hit with force, the pin may fly and injure people in the surrounding area, so check to be sure the surrounding area is safe. When removing the pin, be extremely careful not to stand behind the bucket or to put your foot or any part of your body behind the bucket from the side. When removing or installing the pin, be extremely careful not to get your hands caught.

Never put your fingers in the pin holes when aligning the holes. Stop the machine on a firm, flat surface. When performing joint work, make clear signals to each other and work carefully. BUCKET REPLACEMENT 1. Place the bucket in contact with a flat surface. When removing the pins, place the bucket so that it is in light contact with the ground. If the bucket is lowered firmly to the ground, the resistance will be increased and it will be difficult to remove the pins. Remark After removing the pins, make sure that they do not become contaminated with sand or mud and that the seals of bushing on both sides do not become damaged. 2.

Remove the double nut from the stopper bolt of each pin of the arm and link, remove the bolts, then take out arm pin (A) and link pin (B), and remove the bucket. 3. Align the arm with holes (1) and the link with holes (2), then coat with grease and install pins (A) and (B). PC300LC/HD-7E0 2-119