HOW-TO SECTION does nor require changing until the fuel level has risen to the top of the element, or after one year of service, whichever comes first. To avoid cover or vent dap damage, do not use tools to tighten the vent cap. NOTICE: Engine Out of Fuel — How to Restart When an engine has run out of fuel, there is a definite procedure to follow when restarting it. NOTICE: Do not allow the fuel level in the see-thru cover to fall below the top of the collar, since this may lead to interruption of the fuel flow and engine stalling. NOTICE: The starting motor and fuel pump should never be used to prime the fuel filters.
Prolonged used of the starting motor and fuel pump to prime the fuel system can result in damage to the starter, fuel pump and injectors and cause erratic running of the engine due to the amount of air in the fuel lines and filters. 2. Start the engine and allow the lubrication system to reach its normal operating pressure, then increase engine speed to high idle for 2 to 3 minutes. 3. After the air is purged and with the engine still running, loosen the vent cap on the filter cover. The fuel level in the cover will start falling. When the fuel level falls to the top of the collar on the Fuel Pro cover, tighten the vent cap quickly by hand .
Engines with Fuel Pro Filters Use the following procedure for an engine with Fuel Pro filters. 1. Remove the vent cap from the top of the filter by turning counterclockwise. Fill the cover full of clean fuel. After making sure the O-ring seal is installed on the vent plug, reinstall the plug and tighten by hand only. Engine Mounted Fuel Filter Use the following procedure for an engine mounted fuel filter. 1. If the engine is equipped with a hand priming pump located on the fuel filter module, operate the 96 All information subject to change without notice. DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION