EPA07 MBE 4000 OPERATOR'S MANUAL Always verify that the freeze point and nitrite concentration of the antifreeze/water mix are correct by using a POWER Trac ® 3-Way Test Strip. If chemical analysis is used, elements in the coolant must fall within the limits as listed in Table 13 Table 13 Fully Formulated Glycol Coolant Limits with TMC RP-329, TMC RP-330 Chemistry Type A (50/50 Coolant/Water Mixture) Recycled Antifreeze — Antifreeze or coolant recycled by reverse osmosis, distillation, and ion exchange, properly re-inhibited to meet TMC RP-329 “Type or RP-330 “Type requirements has been demonstrated to provide service equivalent to virgin antifreeze.
Recycled antifreeze or coolants of these types are preferred. Other recycled coolants, especially coolants recycled through filtration processes, are not recommended . Technology (OAT) corrosion inhibitor package. These coolants require less maintenance over the useful life of the engine. The cooling system should either be equipped with a “blank” coolant filter or the coolant filter and piping may be omitted from the system. ETHYLENE GLYCOL / WATER + OAT INHIBITOR, PROPYLENE GLYCOL / WATER + OAT INHIBITOR Ethylene glycol and propylene glycol are also available with an Organic Acid All information subject to change without notice.
103 DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION Fully Formulated Glycol Coolant Concentration Limits Boron 125 – 500 PPM Nitrite 900 – 3200 PPM Nitrate 200 – 3200 PPM Silicon 50 – 250 PPM Phosphorous 0 PPM pH 8.0 – 11.0