HOW-TO SECTION OAT fully formulated antifreezes are available as concentrated and pre-mixed. Concentrated antifreezes should be mixed at 50% (50% antifreeze 50% water). OAT coolants should not be mixed with conventional coolants. If OAT and conventional coolants are mixed, no damage will result, but the long-life advantages of the OAT coolant will be lost. In this event, the coolant should be maintained as a fully formulated ESI (Extended Service Interval) coolant, not as an OAT coolant. cavitation erosion protection. Initial fill options are listed in Table 1. OAT inhibitors such as POWER COOL Plus 6000 are available for water-only systems.
OAT inhibitor should be mixed at 7.5% 10% by volume with water. Refer to section POWER COOL ENGINE PRODUCTS for a listing of POWER COOL products. Conventional SCA ( POWER COOL 3000) can also be used to protect the engine. Listed in Table 14 are POWER COOL 3000 coolant concentration limits. Detroit Diesel markets OAT-inhibited ethylene glycol coolants DDC POWER COOL Plus and POWER COOL Plus Marine (30% glycol, 70% water). POWER COOL Plus coolants contain all of the required inhibitors. If a non-DDC OAT antifreeze is used, it must conform to TMC RP-338 specification. Do not add extender to new OAT antifreeze or coolant. NOTE: Do not use Power Trac 3–Way Test Strips to test OAT coolant.
WATER ONLY + SCA, WATER ONLY + OAT INHIBITOR In warm climates where freeze protection is not required, water only with corrosion inhibitors is approved for use. Water-only systems need to be treated with the proper dosage of corrosion inhibitors. Detroit Diesel-approved conventional SCA or OAT corrosion inhibitors must be added to the water to provide required corrosion and 104 All information subject to change without notice. DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION