MAN — Man EPA07 MBE 4000 Engine Operator's Manual

EPA07 MBE 4000 OPERATOR'S MANUAL Table 14 Power Cool 3000 Concentration Limits (5% Power Cool 3000/ 95% Water) POWER COOL 3000 SCA inhibitors should be mixed at 5% by volume with water (1 quart per 5 gallons of water). These additions can be made by adding liquid SCAs available in a variety of sizes. Coolant filters are also available for different cooling system capacities. These filters release the proper amount of SCA at initial fill. below the maximum allowable limits listed in Table 15. NOTICE: Do not add additional SCA to new, fully formulated antifreeze or coolant. This can result in dropout and/or the formation of deposits.

Water Requirements Distilled or de-ionized water, which eliminates the adverse effects of minerals in tap water, is preferred. High levels of dissolved chlorides, sulfates, magnesium, and calcium in some tap water causes scale deposits, sludge deposits and/or corrosion. These deposits have been shown to result in water pump failures and poor heat transfer, resulting in overheating. If tap water is used, the mineral content in the water must be Coolants Not Recommended The following coolants are not recommended for use in Detroit Diesel engines. All Antifreezes And Coolants Containing Phosphate These coolants are not recommended.

Drop out, overheating and water pump seal failures can result from the use of coolant or inhibitor packages based on phosphate. All information subject to change without notice. 105 DDC-SVC-MAN-0041 Copyright © 2009 DETROIT DIESEL CORPORATION Power Cool 3000 Coolant Concentration Limits Boron 125 – 500 PPM Nitrite 900 – 3200 PPM Nitrate 0 – 1000 PPM Silicon 50 – 250 PPM Phosphorous 0 PPM pH 8.0 – 11.0