Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — REMOVAL AND INSTALLATION OF OPERATOR'S CAB ASSEMBLY

SEN00953-00 50 Disassembly and assembly 1. Installation of seal to air conditioner box 1) Remove dirt, oil and grease from the posi- tion on the top surface of floor frame for coating liquefied sealants. Implement the cleaning on both sides. 2) Coat section (A) on the top surface of floor frame (31) with liquefied sealant, Three Bond 1207B. (See the diagram to the left) 3) Install air conditioner box (32). 4) Coat the section on both sides of air con- ditioner box (32) in contact with U-shaped frame (the range on the floor frame shown in the diagram) for 8 mm with liquid gasket Three Bond 1207B. 7) Coat the outer surface around seal (B) (sealing surface with the cab) with grease (G2-LI).

a This is for improving sliding after installing the cab to prevent disloca- tion and/or deformation of the seal. 5) Coat adhesive (LT-1A) on the inner sur- face around seal (B) (sealing surface with the air conditioner box). 2. Installation of seal to the cab mating surfaces 1) Sling cab assembly. 2) Remove dirt, oil and grease from the seal pasting surfaces. a Take care not to allow the seal to enter under the cab. q General Seeing the diagram, install seals C, D, E, F and G in this order. 6) Set seal (B) inside guide plate (33) of air conditioner box. a Pull seal (B) downward and install by pressing hard on liquid sealant coated in 2).

a Fix with adhesive (LT-1A) so that clearance ( a ) between seal B and the floor frame will be zero. 6 D65EX, PX, WX-15E0