SEN00290-01 10 Structure, function and maintenance standard Monitor panel 1 Outline Check before starting q The monitor panel consists of the monitor sec- tion which outputs an alarm when the machine has any trouble and the gauge section and the display panel which display the machine condi- tion constantly. The monitor panel has a microcomputer, which processes and displays the signals from the sensors, solenoids, and controllers. The items displayed on the monitor section and the gauge section are shown in the topic “Display of monitor panel“.
q After the operation performed when the power is turned ON, if there is any abnormal one in the check-before-starting items, the lamp of that item flashes or the contents of the abnor- mality are displayed on display panel B. Caution items q The caution items are checked constantly while the engine is running. If any item is abnormal, it and warning lamp flash synchronously. In some abnormal cases, the alarm buzzer may sound at this time. Operation When power is turned ON (When starting switch is turned to “on“ position) q All the LC segments and lamps of the monitor panel light up for 2 seconds and the alarm buzzer sounds for 2 seconds. 4 D65EX, PX, WX-15E0