Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — MEASURING ENGINE SPEED

SEN00585-00 30 Testing and adjusting 5. Measuring torque converter stall speed 1) Start the engine and set the fuel control dial in the low idle position. 2) With the brake pedal depressed securely and the parking brake lever in the “free” position, set the PCCS lever in the “for- ward” and 3rd gear speed position. a Before going to the next step, check that the upper display unit of the mon- itor panel is set in the normal display state and it displays [ F3 ]. a Keep the steering unit in neutral. 3) Press the decelerator pedal and set the fuel control dial in the high idle position. 4) Return the decelerator pedal slowly to stall the torque converter with the engine at high idle.

a The engine speed can be measured by the following operation: q “Pm clinic auxiliary mode” of the monitor panel q Each time the information switch is set to the right or left when the monitor panel is in the normal display state, the display in the multi information section turns to the display of service meter or engine speed. (However, mea- sure the high idle speed of the engine in the “Adjustment mode“). k Keep pressing the brake pedal securely and keep your right foot on the decelerator pedal for safety until the work is finished. 5) Just after the power train oil temperature gauge reads the top line of the green range, return the direction of the PCCS lever into neutral.

6) Repeat above steps 2) – 5) 3 times. 7) Perform steps 2) – 4) again and measure the engine speed about 5 seconds after the power train oil temperature gauge reads the top line of the green range. a After finishing measurement, return the direction of the PCCS lever into neutral and lower the power train oil temperature with the engine at high idle. 6 D65EX, PX, WX-15E0