30 Testing and adjusting SEN00585-00 18. Disconnect connector CE03 of engine controller. 6) Tighten bolts (12) to the specified torque. a Tighten bolts diagonally so that the upper surface of holder (13) becomes parallel to the upper surface of the cylinder head. q Maximum angle limit: 2.4° 3 Bolt: 9.8 ± 2.0 Nm {1.0 ± 0.2 kgm} 7) Tighten inlet connector (11) to the speci- fied torque. 3 Retainer (10): 40.2 ± 3.9 Nm {4.1 ± 0.4 kgm} Apply the caulking compound ( e ) (hatched section) to retainer (10) and the cylinder head. 2 Caulking compound: GE TOSHIBA SILICON TOSSEAL 381 k Be sure to disconnect the connector.
Otherwise, engine may start during the measurement and this may create a dangerous condition. k Since connector (CE03) includes the power source circuit of engine control- ler, cover the connector on the harness side with a vinyl sheet, etc. to prevent electric leakage and grounding fault. 19. Crank the engine with the starting motor and check the compression pressure. a Measure the pressure when the pointer of the gauge is stabilized. 20. When the checking is completed, remove the instruments and reinstall the removed parts. a Install the injector and the inlet connector according to the following procedure.
1) Coat the O-ring of injector (14) and the mounting hole on the head with engine oil (EO15W-40). 2) Assemble holder (13) on injector (14) then insert the assembly into the cylinder head with the fuel inlet hole of injector (14) on the intake manifold side. 3) Tighten bolt (12) by three or four threads with hands. 4) Coat the O-ring of inlet connector (11) and the mounting hole on the head with engine oil (EO15W-40). 5) Install inlet connector (11) temporarily with retainer (10). 3 Retainer: 14.7 ± 5.0 Nm {1.5 ± 0.5 kgm} D65EX, PX, WX-15E0 17