30 Testing and adjusting SEN00585-00 Emergency escape method when power train has trouble 1 2) Remove the cover on the left of the toe board and connect wring harness [2] to PL1 connector (1) and PL2 connector (2). a Devices used for emergency escape q PL1 connector (1): Connect to male side and female side. q PL2 connector (2): Connect to female side. a PL2 connector on the male side is kept disconnected, mask it with a vinyl sheet, etc. 1.
Emergency escape method by the switch box (Use L1) a If the machine cannot be moved because of a trouble in the electric system of the power train control unit (travel direction, gear speed, steering), carry out the emer- gency escape according to the following procedure. a The engine must be able to start during implementing this procedure. If the engine cannot be started, see “Emergency escape method with brake releasing device”. 1) Connect switch assembly [1] and L2 to wining harness [2] of emergency escape device. 3) Open the battery cover on the left of the cab and remove the cover of relay box (3).
k To prevent the machine from start- ing suddenly, set all the gear speed switches of switch assembly [1] to OFF position and the direction switch in P position. D65EX, PX, WX-15E0 43 Symbol Part No. Part name L 1 19M-06-32820 Switch assembly 134-06-72810 Wiring harness 2 7824-66-6430 Prolix resistance 7827-10-1520 Prolix resistance 3 790-190-1601 Pump assembly 4 799-101-5220 Nipple (10 x 1.25 mm) 07002-11023 O-ring