30 Testing and adjusting SEN00585-00 2. Emergency escape method with brake releasing device (Use L3) a If the engine cannot be started and the parking brake cannot be released, carry out the emergency escape according to the following procedure. a Operate after putting a block, etc. on the crawler as a lock so that machine cannot move on a downhill slope. 1) Assemble pump assembly L3 . 3) Remove inspection plug for measuring oil pressure which is located within the inspection cover on the right outer side of the operator cab. 4) Install nipple L4 and connect hose [2] of pump assembly L3 . 5) Turn the starting switch on and set the parking brake lever in free position.
6) Operate the vacuum pump to raise the brake releasing oil pressure to the initial pressure. q Initial pressure: Approx. 2.74 MPa {Approx. 28 kg/cm 2 } a Since an accumulator is installed in the circuit, the handle must be oper- ated 30 – 50 times to raise the oil pressure. a If the oil pressure does not rise above a certain level, the relief valve may be set to low pressure. In this case, adjust the set pressure of the relief valve. 7) Tow the machine to a safe place. a The brake releasing oil pressure low- ers gradually because of internal leakage and the brake is applied again about 1 minute after. Therefore, work immediately.
a If the brake releasing pressure lowers to about 1.57 MPa {16 kg/cm 2 }, the brake is applied. In this case, operate the volume pump again to raise the brake releasing pressure to the initial pressure. 8) When disconnecting the hose after finish- ing the work, loosen the screw slowly and do not stand in the spouting direction of the oil. 2) Install volume pump [1] of pump assembly L3 to the outside of the operator cab. D65EX, PX, WX-15E0 45