30 Testing and adjusting SEN00585-00 Testing control circuit basic pressure 1 3. Install oil pressure pickup adapter N2 and con- nect the disconnected hose again. a Instruments for testing and adjusting control circuit basic pressure 4. Install nipple [1] of hydraulic tester N1 and con- nect oil pressure gauge [2]. a Use an oil pressure gauge of 5.9 MPa {60 kg/cm 2 }. a The control circuit main pressure is the pres- sure lowered by the self pressure reducing valve. It is used commonly for blade PPC, fan pump control, steering EPC and ripper PPC (if equipped).
Measuring k Stop the machine on a level place, lower the work equipment to the ground, and set the parking brake lever and work equip- ment lock lever in the lock position. a Measure the control circuit basic pressure under the following condition. 5. Run the engine at high idle and set the blade lever and ripper lever in neutral and measure the oil pressure. q Hydraulic oil temperature: Within operat- ing range 1. Open the cover of the main control valve at the right side of the operator cab. 2. Disconnect hose (1). 6. After finishing measurement, remove the mea- suring instrument and reinstall the removed parts. Adjusting a The self pressure reducing valve cannot be adjusted.
D65EX, PX, WX-15E0 51 Symbol Part No. Part name N 1 799-101-5002 Hydraulic tester 790-261-1204 Digital type hydraulic tester 2 799-401-3200 Adapter (size 03)