Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — BLEEDING AIR FROM FAN PUMP

30 Testing and adjusting SEN00585-00 Bleeding air from fan pump 1 a If the fan pump was removed and installed or its piping was disconnected and connected, bleed air from the pump case according to the following procedure. a Before performing the following procedure, check that the hydraulic oil is at the specified level. a Remove the operator's seat. 1. Remove the inspection cover on the right of the floor. 2. Loosen air bleeder (1) and leave it for 15 min- utes. 3. After 15 minutes, run the engine at low idle. 4. When oil flows out of air bleeder (1), tighten air bleeder (1). 3 Bleeder: 8.8 ± 1.0 Nm {0.9 ± 0.1 kgm} D65EX, PX, WX-15E0 61