Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — ADJUSTING STRAIGHT TILTDOZER

SEN00585-00 30 Testing and adjusting Adjusting straight tiltdozer 1 a If the blade was removed and installed or dis- assembled and assembled, adjust it according to the following procedure. 1. Adjusting blade tilting distance 1) After installing the blade, adjust installa- tion dimension ( A ) of brace (1) by handle (2). q Installation dimension ( A ) of brace 2. Adjusting shims for blade assembly 1) After assembling the blade, adjust the shims of tilt section (3), center section (4), lift section (5), and trunnion section (6). Adjustment of shims Unit: mm 2) Measure right and left tilting distances ( B1 ) and ( B2 ). Note:

Play of spherical part in axial direction 2) Supply grease to each adjustment section and check that each part rotates smoothly. 2 Adjustment sections (3), (4), (5): Grease (G1-T) 3) If the tilting distances are different remark- ably, adjust installation dimension ( A ) of brace (1) according to the following proce- dure. q ( B1 )>( B2 ): Increase installation dimen- sion ( A ) finely. q ( B1 )>( B2 ): Decrease installation dimen- sion ( A ) finely.

62 D65EX, PX, WX-15E0 PX EX A (mm) 1,147 1,151 Adjustment sections Check item Tilt section (3) Center section (4) Lift section (5) Trunnion section (6) Clearance a b c d Standard clearance Note) 0.2 – 0.7 0.2 – 0.7 0 .2 – 0.7 0.2 – 1.2 Standard thickness of shim 5 5 4 10 PX EX Right tilting distance B1 (mm) Approx. 450 Approx. 440 Left tilting distance B2 (mm) Approx. 450 Approx. 440