Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DGT1KX] POWER TRAIN OIL TEMPERATURE SENSOR: INPUT SIGNAL IS OUT OF NORMAL RANGE

40 Troubleshooting SEN00591-00 Failure code [DGT1KX] Power train oil temperature sensor: Input signal is out of normal range 1 Circuit diagram related to power train oil temperature sensor D65EX, PX, WX-15E0 55 Action code Failure code Symptom of failure Power train oil temperature sensor: Input signal is out of normal range (Steering and transmission controller system) E01 DGT1KX Failure content • Power train oil temperature sensor signal is out of normal range. Controller's action • Nothing particular. Symptoms that appears on machine • Power train oil temperature on monitor panel is not displayed normally. • Fan speed is limited to half. • Gear shift shock of transmission increases.

General information • Power train oil temperature status (temperature) can be checked in monitoring mode. (Code 30100: Power train oil temperature) • Method of reproducing failure code: Turn starting switch ON or start engine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting D 1 pe (S efective power train oil tem- rature sensor hort-circuiting) aPrepare with starting switch OFF and diagnose with starting switch still OFF. 453 (male) Resistance Between (1) – (2) 3.5 k – 90 kz (10 – 100°C) Between (1), (2) – chassis ground Min.

1 Mz D 2 (C efective harness grounding ontact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between S04 (female) (12) – 453 (female) (1) with ground Resis- tance Min. 1 Mz H 3 (C ot short of wiring harness ontact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Wiring harness between S04 (female) (12) – 453 (female) (1) with ground Voltage Max. 1 V D 4 tr efective steering and ansmission controller aPrepare with starting switch OFF and diagnose with starting switch still OFF.

S03, S04 (female) Resistance S04 (12) – S03 (3) (4) 3.5 k – 90 kz (10 – 100°C) Between S04 (12) – ground Min. 1 Mz