Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — FAILURE CODE [DV00KB] ALARM BUZZER: SHORT CIRCUIT

SEN00592-00 40 Troubleshooting Failure code [DV00KB] Alarm buzzer: Short circuit 1 Circuit diagram related to alarm buzzer 8 D65EX, PX, WX-15E0 Action code Failure code Symptom of failure Alarm buzzer: Short circuit (monitor panel circuit) — DV00KB Failure cont ent • Abnormal current flowed in the alarm buzzer circuit when the GND is outputted. Controller' action s • Stops the GND output for alarm buzzer circuit. Symptoms t appears on machin hat • Alarm buzzer does not sound. e General informatio • Duplication of failure code: Turn starting switch ON (When it is turned ON, buzzer sounds for 1 second).

n Possible causes and standard val when norm Cause Defective alarm buzzer 1 (internal short circuit) Hot short of wiring harness the 2 (a contact with 24 V circuit) ues al 3 Defective monitor panel Standard value when normal and remarks for troubleshooting Defective alarm buzzer (internal short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. 217 (male) Continuity Between (2) – (1) Continue Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between 217 (female) (1) – S03 (female) (18) Voltage M ax.

1 V Defective monitor panel aPrepare with starting switch OFF and diagnose with starting switch ON. S03 Alarm buzzer Voltage Between (18 chassis gro When stopping ) – When turned ON und (sounding) 20 – 30 Max. 3 V