Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-25 MALFUNCTION OF WIPERS.

40 Troubleshooting SEN00593-00 D65EX, PX, WX-15E0 57 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 7 Disconnection or short circuit with ground in wiring harness (Disconnection in wiring or defective contact of connec- tors or contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CN12 (female) (4) – CN33 (female) (3) Resis- tance Max. 1 z Between ground and wiring harness between CN12 (female) (4) – CN33 (female) (3) Resis- tance Min. 1 Mz Wiring harness between CN33 (female) (6) – CN32 (female) (4) Resis- tance Max.

1 z Between ground and wiring harness between CN33 (female) (6) – CN32 (female) (4) Resis- tance Min. 1 Mz Wiring harness between fuse (4) – CN12 (female) (2) (3) Resis- tance Max. 1 z Between ground and wiring harness between fuse (4) – CN12 (female) (2) (3) Resis- tance Min. 1 Mz Wiring harness among fuse (4) – CN32 (female) (3) – CN37 (female) (3) Resis- tance Max. 1 z Between ground and wiring harness among fuse (4) – CN32 (female) (3) – CN37 (female) (3) Resis- tance Min. 1 Mz Wiring harness between CN32 (female) (5) – CN37 (female) (1) Resis- tance Max. 1 z Between ground and wiring harness between CN32 (female) (5) – CN37 (female) (1) Resis- tance Min.

1 Mz Wiring harness between CN32 (female) (6) – ground Resis- tance Max. 1 z Wiring harness between CN37 (female) (2) – ground Resis- tance Max. 1 z