40 Troubleshooting SEN00594-00 H-2 Machine does not move (at 2nd or 3rd speed) 1 D65EX, PX, WX-15E0 5 Symptom of failure • Machine does not move (at 2nd or 3rd speed) General information • Check that the power train oil level is normal before troubleshooting. Check that the transmission main relief pressure is normal before troubleshooting. (See H-1 “There is no travel power”.) Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Internally defective torque converter aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting.
PCCS lever Torque converter inlet pressure Torque converter outlet pressure Full neutral Max. 0.88 MPa {Max. 9 kg/cm2} 0.39 – 0.69 MPa {4 – 7 kg/cm2} 2 Defective operation of trans- mission valve (ECMV) aPrepare with the starting switch OFF, and then run the engine at low idle for troubleshooting. Transmission clutch Clutch pressure 2ND Min. 2.84 MPa {Min. 29 kg/cm2} 3RD Min. 2.84 MPa {Min. 29 kg/cm2} 3 Internally defective transmission clutch The transmission clutch (2nd or 3rd speed) is assumed to be defec- tive internally; visually check it. 4 Defective operation of parking brake (dragging) The parking brake operation is assumed to be defective (dragging); check the linkage valves.
5 Defective operation of brake (dragging) aMove to a flat place (a hard road), and start the engine for trou- bleshooting. If the machine does not run by low idle + F2 operation, brake drag- ging occurs. (Carry out troubleshooting “H-8 Brake does not work“.) 6 Internally defective transmission The transmission is assumed to be defective internally; visually check it.