Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — H-4 MACHINE TRAVELS ONLY IN ONE DIRECTION, FORWARD OR IN REVERSE

40 Troubleshooting SEN00594-00 H-4 Machine travels only in one direction, forward or in reverse 1 D65EX, PX, WX-15E0 7 Symptom of failure • Machine travels only in one direction, forward or in reverse. General information • Check that the power train oil level is normal before troubleshooting. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective power train pump The power train pump is assumed to be defective; visually check it. 2 Defective set pressure or internal defect of transmis- sion main relief valve aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting.

PCCS lever Transmission main relief pressure Full neutral Min. 3.04 MPa {Min. 31 kg/cm2} aPrepare with starting switch OFF and diagnose with starting switch still OFF. Visually check that the free length of spring and the number of shims are normal and also that the spool rotates smoothly. • Free length of large spring: 128 mm • Free length of small spring: 108 mm • Number of shims: 6 3 Defective operation of trans- mission valve (ECMV) aPrepare with the starting switch OFF, and then run the engine at low idle for troubleshooting. (Before this, check that the transmission main relief pressure is normal.) Transmission clutch Clutch pressure FWD Min. 2.84 MPa {Min. 29 kg/cm2} REV Min.

2.84 MPa {Min. 29 kg/cm2} 4 Defective transmission clutch seal If the result of the troubleshooting in cause 3 is abnormal, the clutch seal is assumed to be defective; visually check it. 5 Internally defective transmission clutch The transmission clutch (forward or reverse) is assumed to be defective internally; visually check it.