Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — H-9 OVERHEAT OF POWER TRAIN OIL

40 Troubleshooting SEN00594-00 H-9 Overheat of power train oil 1 D65EX, PX, WX-15E0 11 Symptom of failure • The power train oil overheats. General information • Check that the power train oil level is normal before troubleshooting. • Check that the reading on the power train oil temperature gauge matches the actual oil temperature before troubleshooting. (If they do not match, carry out troubleshooting “Reading on power train oil temperature gauge is incorrect”. • Check that the transmission main relief pressure is normal before troubleshooting.

(See H-1 "There is no travel power") Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective engine system The engine cooling system is assumed to be defective or the engine output is assumed to be increased; see the shop manual of engine volume. 2 Defective power train pump or residual air from suction circuit The power train pump is assumed to be defective or residual air from the suction circuit is assumed to remain; visually check it. 3 Internally defective torque converter aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting.

PCCS lever Torque converter inlet pressure Torque converter outlet pressure Full neutral Max. 0.88 MPa {Max. 9 kg/cm2} 0.39 – 0.69 MPa {4 – 7 kg/cm2} 4 Defective operation of trans- mission clutch (Slip) The transmission clutch is assumed to be defective internally (slip); visually check it. 5 Defective operation of brake (Dragging) aStart the engine to diagnose. 1. Run the engine at low idle on a flat place (a hard road). 2. Set the gearshift lever in F2. 3. See if the machine moves (travels). If it does not move, brake dragging occurs. (Carry out troubleshooting “H-8 Brake does not work”.)