Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — H-11 ALL WORK EQUIPMENT SPEEDS ARE SLOW

SEN00594-00 40 Troubleshooting H-10 Abnormal sound comes out from around HSS and work equipment pump or HSS motor 1 H-11 All work equipment speeds are slow 1 12 D65EX, PX, WX-15E0 Symptom of failure • Abnormal noise comes from around HSS and work equipment pump. General information • Check that the hydraulic oil level is normal before troubleshooting. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Inappropriate oil The oil used is assumed to be inappropriate; visually check it. 2 Clogged hydraulic tank strainer The hydraulic tank strainer is assumed to be clogged; visually check it.

3 Air inhaled in suction circuit Air is assumed to be inhaled in the suction circuit of the HSS and work equipment pump; visually check the pipes. 4 Internally defective HSS pump The HSS and work equipment pump is assumed to be defective internally; visually check it. 5 Internally defective HSS motor The HSS motor is assumed to be defective internally; visually check it. Symptom of failure • All work equipment speeds are slow. General information • Check that the oil level in the hydraulic tank is normal before troubleshooting.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective PTO (pump drive unit of HSS and work equip- ment) The PTO pump drive unit of the HSS and work equipment is assumed to be defective; visually check it. 2 Defective HSS and work equipment pump The HSS and work equipment pump is assumed to be defective; visually check it. 3 Defective operation of unload valve aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting.

Work equipment control lever Unload pressure Full neutral 3.43 (+1.37/0) MPa {35 (+14/0) kg/cm2} 4 Defective set pressure or defective operation of main relief valve aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting. Work equipment control lever Main relief pressure Stroke end Min. 19.6 MPa {Min. 200 kg/cm2} 5 Defective operation of self pressure reducing valve (PPC basic pressure) aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting.

Work equipment control lever Basic pressure of control circuit Full neutral 4.27 ± 0.25 MPa {43.5 ± 2.5 kg/cm2} 6 Internally defective PPC valve If the result of the troubleshooting in cause 5 is abnormal, the PPC valve is assumed to be defective internally; visually check it.