40 Troubleshooting SEN00594-00 H-12 Work equipment does not move 1 H-13 Blade lift speed is slow or lacks power 1 D65EX, PX, WX-15E0 13 Symptom of failure • Work equipment does not move. General information • Check that the oil level in the hydraulic tank is normal before troubleshooting. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective PTO (pump drive unit of HSS and work equip- ment) The PTO pump drive unit of the HSS and work equipment is assumed to be defective; visually check it. 2 Defective HSS and work equipment pump The HSS and work equipment pump is assumed to be defective; visually check it.
3 Defective operation of unload valve aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting. Work equipment control lever Unload pressure Full neutral 3.43 (+1.37/0) MPa {35 (+14/0) kg/cm2} 4 Defective set pressure or defective operation of main relief valve aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting. Work equipment control lever Main relief pressure Stroke end Min. 19.6 MPa {Min. 200 kg/cm2} 5 Defective operation of self pressure reducing valve (PPC basic pressure) aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting.
Work equipment control lever Basic pressure of control circuit Full neutral 4.27 ± 0.25 MPa {43.5 ± 2.5 kg/cm2} Symptom of failure • Blade lift speed is slow or lacks power. General information • Check that the oil level in the hydraulic tank is normal before troubleshooting. • Check for modifications to the blade. • If the hydraulic drift of blade lift is also excessive, carry out the troubleshooting of "H-16 Excessive hydraulic drift of blade lift" first.
Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective operation of PPC valve aPrepare with the starting switch OFF, and then run the engine at high idle for troubleshooting. Blade control lever PPC valve output pressure Lift stroke end 3.53 – 4.41 MPa {36 – 45 kg/cm2} 2 Defective operation of blade lift control valve (spool) The operation of the blade lift control valve spool is assumed to be defective; visually check it. 3 Residual air in blade lift cylin- der Residual air is assumed to remain in the blade lift cylinder; bleed air and observe how the phenomenon changes.