Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — REMOVAL AND INSTALLATION OF FUEL SUPPLY PUMP ASSEMBLY

50 Disassembly and assembly SEN00945-00 [*1] a Use a new MIKALOR clamp. a Set the hose to the original (marked) position. (Insertion depth of air hose: 57 mm) a Set the bridge (BR) so that its clamp bolt will be at the bottom and it will be lapped over band (BD) by at least min. 5 mm. [*3], [*5] q High-pressure pipe, high-pressure pipe clamp and bracket 1) Tighten bracket (21), high-pressure pipe (17), and clamp (15) in order with the fin- gers. 2) Tighten the sleeve nut of high-pressure pipe (17). 2 Threads of clamp bolt: Lubricating oil: THREEBOND, PAND18B a Do not use an impact wrench. 3 Sleeve nut: 37.3 ± 4 Nm {3.8 ± 0.4 kgm} 3) Install right and left bellows (16).

4) Tighten clamp (15) and bracket (21) per- manently in order. q When reusing the hose a Set the clamp to its original position. 3 MIKALOR clamp: Min. 6 Nm (1.6 kgm} q When using a new hose a Tighten until band gap (BDG) is 5 – 8 mm . [*4] 3 Joint bolt of lubrication tube (18): 24 ± 4 Nm {2.45 ± 0.41 kgm} [*5] See [*3]. [*2] a See Testing and adjusting, “Testing and adjust- ing air conditioner compressor belt tension”. [*6] q Fuel tubes (23), (24) and (25) k The internal parts of the adapters may be damaged when fuel tubes (23), (24) and (25) are removed. Accordingly, replace the adapters with new ones. D65EX, PX, WX-15E0 5