Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — REMOVAL AND INSTALLATION OF CYLINDER HEAD ASSEMBLY

SEN00945-00 50 Disassembly and assembly [*6] a Use a new MIKALOR clamp. a Set the hose to the original (marked) position. (Insertion depth of air hose: 57 mm) a Set the bridge (BR) so that its clamp bolt will be at the bottom and it will be lapped over band (BD) by at least min. 5 mm. 2 Threads of clamp bolt: Lubricating oil: THREEBOND, PAND18B a Do not use an impact wrench. q When reusing the hose a Set the clamp to its original position. 3 MIKALOR clamp: Min. 6 Nm (1.6 kgm} q When using a new hose a Tighten until band gap (BDG) is 5 – 8 mm . 1. Install common rail (59) temporarily (Tighten the bolts with the fingers). 2. Tighten drain tube (58) temporarily. 3.

Install tube (41) between the supply pump and common rail. 3 Nut: 37.3 ± 4 Nm {3.8 ± 0.4 kgm} 4. Install bracket (46) and tighten clamp (39) tem- porarily. 5. Install tubes (52) – (57) between the common rail and injector. 3 Nut: 37.3 ± 4 Nm {3.8 ± 0.4 kgm} 6. Tighten drain tube (58) permanently. 3 Joint bolt: 24 ± 4 Nm {2.4 ± 0.4 kgm} 7. Tighten common rail (59) permanently. 3 Joint bolt: 43.1 ± 4.0 Nm {4.4 ± 0.4 kgm} [*7] a Adjust the air conditioner compressor belt ten- sion. For details, see Testing and adjusting, “Testing and adjusting air conditioner compres- sor belt tension”. 8. Tighten clamp (39) and bracket (46) perma- nently.

[*8] q High-pressure pipe and common rail k Do not bend the high-pressure pipe to col- lect before installing. k Be sure to use the genuine high-pressure pipe clamps and observe the tightening torque. k Install each high-pressure pipe and wiring harness at least 10 mm apart from each other. a When installing each high-pressure pipe, check the taper seal of its joint (Part "a": Part of 2 mm from the end) for visible lengthwise slit "b" and spot "c" and check part "d" (End of taper seal: Part at 2 mm from the end) for stepped-type wear caused by fatigue which your nail can feel. If there is any of those defects, it can cause fuel leakage. In this case, replace the high-pressure pipe.

16 D65EX, PX, WX-15E0