Operator Cab And Controls - Section 32 OM3242 Page 32-26 C6. Propel System Not Ready The amber indicator light func- tions during start-up much like the hour glass icon on a com- puter screen. This light indicates the computer is in the process of performing the self-diagnos- tics and set-up functions at start-up. Propulsion will not be available at this time. VEHICLE HEALTH MONITORING SYSTEM (VHMS) Operation This system uses VHMS controller (2, Figure 32-10) to gather data about the operation of the truck from sensors and other controllers installed on the truck.
The data stored in the VHMS controller is collected by a laptop personal computer (PC) or transmitted directly by communications satellite (utilizing the Orb- comm controller). This data is then compiled at the Komatsu computer server. Based on this information, the servicing Komatsu distributor will suggest improvements and provide information aimed at reducing machine repair costs and downtime. D6. Reduced Propulsion The amber “reduced propulsion” light is used to indicate that the full AC drive system performance in propulsion is not available. At this time, the only event that should activate this light is the use of “limp home mode”.
This mode of operation requires a technician to enable. When the data-store button (1, Figure 32-9) is pressed on the back side of the center console, it will store a “snapshot” of the Statex III drive system. It will also trigger the VHMS system to store a “snapshot” of the truck operating system. A light (2, Figure 32-9) will stay illuminated while the VHMS system is recording the “snapshot”, which lasts for 7.5 minutes. The VHMS system is turned on by the truck key switch. Immediately after receiving 24V power from the key switch, the VHMS controller begins the power-up initialization sequence.
This sequence takes about three seconds, during which time the red LED digits (4, Figure 32-10) display a circular sequence of flashing LED segments. E6. Retard At Continuous Level The amber retard at continuous level light indicates that the retarding effort is at the continu- ous level. The operator must control the speed of the truck in accordance to the "continuous" speeds on the GRADE/SPEED RETARD CHART on page 32-4. E7. Maintenance Monitor The indicator light will illuminate if a “repair” fault is detected, which must be corrected after the operator’s shift is done. FIGURE 32-9. CENTER CONSOLE, REAR VIEW 1. Data Store Button 2. VHMS Snapshot In Progress Light