Komatsu — LEVELLING BLADE

OPERATION 2 Mechanical Tilt 1. Raise blade 400 to 500 mm (15.8 to 19.7 in) above ground, then put blocking under the C frame. Make sure that all of the load is off of the upper struts before the lower strut is removed from the C frame bracket. 2. Remove the strut trunnion from its bracket on the side to be raised, and position strut close to the C frame. 3. Adjust the opposite side to get the desired tilt by shortening the up- per strut. Adjust this strut to tilt the blade about half of the desired tilt. Always lower the side being adjusted first so lack of balance will not cause the loose strut assembly to swing out and cause unexpected injury or damage. 4.

Return to the side of the machine on which the strut assembly was disengaged, and lengthen the upper strut until the strut trunnion can be inserted in its bracket on the C frame. 5. After tilting the blade, raise the blade and lengthen the upper struts so there is a compression bind on them to eliminate free play. Whenever the blade is tilted, adjustments to one upper strut must always be equal and opposite to the adjustment made on the other strut. For ex- ample: if a strut on one side is shortened 1/2 turn, lengthen the opposite strut 1/2 turn. 2 LEVELLING BLADE 2 Hydraulic Tilt Position blade with tilted corner on ground, using cylinders level the blade. 2 Mechanical Tilt 1.

Raise blade 400 to 500 mm (15.8 to 19.7 in) above ground, then put blocking under the C frame. 2-74 D87E-2 D87P-2