ELECTRONIC CONTROL SYSTEM B+ MAF ECM MICRO- PROCESSOR B+ SIGNAL CONTROL VREF SIG RIGHT BANK INJECTORS X1 X1 LEFT BANK INJECTORS X2 X3 X2 X3 THERMISTOR HEATED ELEMENT X1-7 IAT GRD X1-6 IAT SIG GRD X1 IDM X2-2 MAF X2 X3 FIXED RESISTOR FIXED RESISTOR X4 EGR DRIVE MODULE MAF / IAT ECM ACT GRD 4 ENGINE IN-LINE 12-WAY CONNECTOR E D C B A KEY PWR 9 MAF SIGNAL KEY POWER ACTUATOR GRD SIGNAL GRD IAT BCS IPR EGR VALVE Mass Air Flow (MAF) Sensor • The MAF sensor is used to measure the mass of the fresh air portion of the intake air charge. To reduce Oxides of Nitrogen (NOx), a portion of the fresh air charge is displaced with cooled exhaust gases.
Sensor Construction The sensor housing contains two sensors, the MAF sensor and the Intake Air Temperature (IAT) sensor. The MAF sensor contains a heated element placed in the air stream. The amount of electrical power needed to maintain the element at the proper temperature depends directly on the mass of air moving over the element. During operation, when voltage is applied to the bridge, the temperature of the heated element increases and the resistance decreases. This affects the output of the divider circuit. The thermistor side is affected only by ambient air temperature.
The divider voltages are compared and the input voltage to the bridge is increased or decreased until both divider voltages are equal. The ECM calculates the total engine gas flow based on MAT, MAP and RPM. The ECM then determines the required EGR percent based on the current engine operating conditions. At this point, the ECM commands the exhaust portion of the total charge through the EGR valve while monitoring the fresh air portion through the MAF sensor. Sensor Operation The MAF sensor is made up of two voltage divider circuits. A thermistor and a fixed resistor make up one voltage divider circuit, and the heated element and a fixed resistor make up the other voltage divider circuit.
The two voltage divider circuits are combined into a bridge circuit with a common power supply and a common ground. An increase or decrease in airflow will change the ratio between the divider voltages, which results in a change to the supply voltage. The signal controller circuit measures the voltage to the bridge and, based on that value, sends a frequency signal to the ECM. The correct key-on, engine-off frequency is 400+100 Hz. 34 International ® VT 275 V6 Engine