C Series Troubleshooting Overview Section TS - Troubleshooting Symptoms Page TS-29 Coolant Temperature Above Normal - Sea Water Cooling System This is symptom tree t026-156 Cause Correction STEP 1 Sea water inlet valve is not open or is partially ............. Check sea water inlet valve. Refer to Procedure 008-103. open OK Go To Next Step STEP 2 Sea water strainer clogged ............. Clean sea water strainer. Refer to Procedure 008-067. OK Go To Next Step STEP 3 Sea water hose(s) collapsed ............. Check sea water system hose(s). Refer to Procedure 008-104. OK Go To Next Step STEP 4 Sea water inlet restriction is excessive ............. Determine cause of inlet restriction.
Refer to Procedure 008-103. OK Go To Next Step STEP 5 Sea water pump outlet pressure is excessive ............. Determine cause of sea water system blockage. Refer to Procedure 008-057. OK Go To Next Step STEP 6 Sea water pump is not pumping water ............. Inspect the sea water pump impeller. Refer to Procedure 008-057.