Troubleshooting Overview C Series Page TS-44 Section TS - Troubleshooting Symptoms Engine Noise Excessive — Connecting Rod This is symptom tree t049 Cause Correction Check the oil level. Verify the dipstick calibration and the oil pan capacity. Fill the system to the specified level. Refer to Procedure 007-009 and Procedure 007-025. STEP 1 Lubricating oil level is below specification ............. OK Go To Next Step STEP 2 Lubricating oil pressure is below specification ............. Check the oil pressure. If the pressure is low, refer toProcedure 007-025. OK Go To Next Step Refer to Cummins Lubricating Oil Reccomendations, Bulletin 3810240 and the Lubricating Oil Contaminated symptom tree.
STEP 3 Lubricating oil is thin or diluted ............. OK Go To Next Step STEP 4 Crankshaft journals are damaged or out of round ............. Inspect the crankshaft journals. Refer to Procedure 001-016. OK Go To Next Step STEP 5 Connecting rod is bent or out of alignment ............. Remove and inspect the connecting rods. Refer to Procedure 001-014. OK Go To Next Step STEP 6 Connecting rod capscrews are loose or not ............. Check the torque on the connecting rod capscrews. Refer to Procedure 001-014. tightened correctly OK Go To Next Step STEP 7 Connecting rod bearings are damaged or worn, are not assembled correctly, or are the wrong .............
Inspect the connecting rod bearings. Refer to Procedure 001-005. bearings