Engine Storage - Long Term C Series Page 0-12 Section 0 - Complete Engine - Group 00 Operate the engine at 1000 to 1200 rpm for 8 to 10 minutes to check for correct engine operation, unusual noises, and coolant, fuel, or lubricating oil leaks. Repair all leaks and component problems as needed. Refer to the appropriate sections. Refer to the following procedures for the Engine Run-in and Testing Procedures. 014-002 014-003 014-004 Engine Storage - Long Term (000-005) General Information WARNING Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50°C [120°F] before removing the pressure cap. Heated coolant spray or steam can cause personal injury.
WARNING Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations. CAUTION After 24 months in storage, the engine cooling system must be drained and flushed with a suitable solvent or a hot, lightweight mineral oil. Repeat flushing procedure a second time before being put back into service. This procedure describes the proper method for the long-term (more than 6 months) storage of an engine that is currently in running condition. This procedure applies to this engine either remaining in chassis - or being removed out of chassis upon completion of the steps below.
Prepare the Engine for Long Term Storage DO NOT use fuel system preservative oil on Natural Gas or Propane Engines. CAUTION Operate the engine at high idle until the coolant temperature is 70°C [158°F]. Turn the engine off. Drain the oil. Install the drain plugs. Fill the engine oil pan sump to the high mark using Tectyl™ 910 or equivalent engine preservative oil. This will provide long term engine rust protection. The oil must meet military specification MIL-PRF-21260, Type P-10, Grade 2, SAE 30. Internal Preservation of the Fuel System with Mechanically and Electronically Actuated Injectors.
CAUTION DO NOT use diesel fuel containing bio components for internal preservation of fuel system for engine storage. Fuel properties degradation may cause damages and lead to premature failure of fuel system components. Disconnect the fuel lines to the engine fuel filter and the injector return line. Use Diesel Pump and Injector calibration fluid that meets ISO 4113 standard, SAE J967d standard and Bosch VS 15665-OL standard. NOTE: Using calibration fluid allows storage for up to 12 months. After 12 months the engine fuel system must be drained and flushed again with fresh calibration fluid. Repeat after each 12-month period.
Alternatively you can use the diesel fuel with 0 percent bio components content for Internal Preservation of the Fuel System.