Fuel Injection Pumps, In-Line C Series Page 5-14 Section 5 - Fuel System - Group 05 Slowly rotate the crankshaft clockwise , as viewed from the front of the engine, until fuel flow from cylinder number 1 begins. The plunger number 1 element is now approaching port closure. Continue to rotate the crankshaft slowly until the flow is reduced to a drip. At the point that the steady stream of flow changes from a solid flow to a drip, stop. This is the static timing position of the fuel injection pump. If the flow does not slow down to a drip: Check the position of the governor lever. Make certain that the cylinder number 1 is before top dead center on the compression stroke.
Turn off the spill port pump. Check the degree wheel on the vibration damper to see what engine degree the timing pointer is indicating. This is spill port static timing. Compare this number to the timing specification for your particular application. If the fuel injection pump static timing, as measured by the above method, is not within specification, remove the large nut that fastens the fuel injecting pump camshaft to the fuel pump drive gear. If the crankshaft has rotated, turn on the spill port pump and rotate the crankshaft to find port closure. Turn off the spill port pump.