Lubricating Oil Cooler C Series Page 7-4 Section 7 - Lubricating Oil System - Group 07 Clean and Inspect for Reuse When using solvent, acids, or alkaline materials for cleaning, follow the manufacturer's recommendations for use. Wear goggles and protective clothing to reduce the possibility of personal injury. WARNING CAUTION Use a solvent that will not harm copper to clean the oil cooler elements. Clean the sealing surfaces of the cylinder block and the oil cooler cover. NOTE: Replace the lubricating oil cooler if any debris is found or if the engine has had a debris-generating failure.
CAUTION Do not reuse an oil cooler core after a debris related engine malfunction since there is no practical method for cleaning the cooler core. Metal particles which can circulate through the lubricating oil system can remain in the cooler core and cause engine damage. If any debris is suspected to have gone through the engine, or if troubleshooting a lubricating oil pressure issue, remove and inspect the lubricating oil pressure regulator located in the lubricating oil cooler cover. Replace if necessary. Refer to Procedure 007-029 in Section 7. If any debris is suspected to have gone through the engine, inspect the oil filter bypass valve located in the lubricating cooler cover.
Make sure the valve is fully seated and opens and closes freely. Replace if necessary. The bypass valve requires a 345 kPa [50 psi] pressure differential to open.