C Series Coolant Thermostat Section 8 - Cooling System - Group 08 Page 8-13 Suspend the thermostats and a 100°C [212°F] thermometer in a container of water. NOTE: Do not allow the thermostats or thermometer to touch the container. Heat the water slowly so the wax element in the thermostats has sufficient time to react to the rising water temperature. NOTE: The normal operating temperature is stamped on the thermostat. Inspect the thermostats as follows: Thermostat must begin to open within 1°C [2°F] of 82°C [180°F]. Thermostat must be fully open within 1°C [2°F] of 95°C [203°F]. NOTE: The fully open clearance between the thermostat flow valve and flange must be 41.5 mm [1.63 in] minimum.
Install Install the thermostats on top of the service shim(s) in the thermostat flanges. They can be within 0.23 mm [0.009 in] of flush with the top of the block, without being above the top of the block. Install a new thermostat gasket.