Coolant Thermostat C Series Page 8-14 Section 8 - Cooling System - Group 08 Position the thermostat housing and belt tensioner over the thermostats and gasket. NOTE: If an external bypass system is used, the thermostat housing support (between the thermostat housing and cylinder block) must be installed. Make sure the gasket is aligned with the capscrew holes. Install the capscrews and finger-tighten. Install the water outlet connection. Tighten all capscrews. Torque Value: 24 N•m [ 212 in-lb ]