Cummins — 3666003

Cooling System C Series Page 8-24 Section 8 - Cooling System - Group 08 Place the coolant dam over the coolant fill neck in the radiator or overflow tank. The size of the fill neck will differ between OEMs. Choose the appropriate sized coolant dam rubber adapters. Switch the coolant replacement tool control lever (1) to “VAC” and leave the service hose valve (2) closed. This will create a vacuum in the tank to evacuate coolant from the cooling system package. Monitor the gauge (3) and build a vacuum of approximately 508 mm-Hg [20 in-Hg] in the coolant replacement tool tank. Slowly open the service hose valve (2) by turning it clockwise until it is completely open approximately ј turn.

Once the cooling system is put into a vacuum, any air trapped in the cooling system will be evacuated through the top of the system. This is noticed as air bubbles through the overflow tank or top of the radiator. When air bubbles are no longer being drawn to the top of the cooling system move the control lever to the middle position. Remove the vacuum on the coolant replacement tool tank by opening the pressure relief valve located on the control block of the coolant replacement tool (1). Remove the coolant dam from the radiator fill neck or overflow tank. Disconnect the coolant replacement tool from the regulated shop air supply. Install the radiator cap.

Drain Marine Applications Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50°C [120°F] before removing the pressure cap. Heated coolant spray or steam can cause personal injury. WARNING WARNING Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations. Avoid excessive contact, and wash thoroughly after contact. Keep out of reach of children.